South Africa · in force since 1 October 2025
The Chief Inspector of Mines’ guideline on preventing fires at mines
It lists trackless mobile machinery first among the main sources of mine fires, and each mine writes its own mandatory code of practice from it.10
584fire incidents reported at mines, 2019 to 2023
Fire suppression suited to each vehicle, and custom on-board suppression on large ore loading and transport vehicles.
The fire engine management unit (FEMS) monitors the suppression cylinder’s pressure and has an output to release it. Pressure faults and releases on the incident record are next.Coming soon
Considering temperature sensors at the hottest points of diesel engine exhausts and retarders.
The wireless sensor (WFS) takes a thermal probe or a linear heat cable and reports to the same alarm. Where they go is agreed with your installer.
Ways to stop engines safely in an emergency, with the fuel shut off.
FEMS has an engine cut output. Recording each cut on the alarm’s timeline is next.Coming soon
Fire detection and fire-fighting equipment maintained at specified intervals by suitably qualified people, with defects recorded and repaired.
Each service is recorded with its date, technician, certificate and next due date, with reminders before it’s due. Defects are logged when they are found and cleared with the repair date and the technician’s registration, and a weekly operator check fills the weeks between services.
Records of the mobile equipment operating at the mine.
Every vehicle with its installation sign-off, zones, self-tests, services and incidents, exportable for the mine’s audits.